The combined application and drainage period should be at least 10 minutes.

Penetrant ApplicationĪpply penetrant to the surface and leave for a suitable dwell period. Ensure that the component is completely dry and not too hot or cold (between 10 ☌ and 50 ☌ or 50 ☏ and 122 ☏). Pre-CleaningĪll surface contamination such as rust, paint residues, grease, scale etc. However, where relevant, the process specifications of the approving authorities must be followed. The following process sequence illustrates the recommended method of use for general industrial applications.

Method of useĪrdrox® 970P25E and 970P26E may be applied by brushing or tank immersion. (Questi sono valori tipici e non costituiscono specifica). Rolls Royce – CSS 232 & OMat 632J (P25E only)Īsk your Chemetall representative for a complete list of approvals Physical and Chemical PropertiesĪspetto fisico: Liquido limpido giallo fluorescenteĭensità a 20☌: circa 0,970 ÷ 0,990 g/mlįlash point: >93☌, comunque superiore a 210☌ International Aero Engines – V2500 (P25E only) ASME – Boiler & Vessel Code (conformance)